With AOI Exchange, developers can purchase pre-built PLC & HMI modules from approved vendors in our marketplace. Save countless hours of development time on your next project.Browse Modules
reads the PLC date and returns a value from 1 to 7 as an integer value for the day of the week
25.00 (CAD)
TYPICAL ANALOG INPUT with M.O.S.
Takes the input from the analog card.
Outputs a scaled value and HH/HI/LO/LL alarms.
Maintenance override switch functionality.
19.99 (CAD)
TYPICAL ANALOG INPUT
Takes the input from the analog card.Outputs a scaled value and HH/HI/LO/LL alarms.
Can be imported as a library and it will create all the variables automatically or can be imported as a AOI.
15.00 (CAD)
Bang-Bang Control
The module provides On-Off control based on 2 setpoints.
25.00 (CAD)
Event Per Hour
This module records the number of events in a 1 hour period.
25.00 (CAD)
E3Plus Interface (DeviceNet)
This module is used to interface the data read from and written to a E3Plus Relay using DeviseNet.\
25.00 (CAD)
MOV Status
This module is used to condition the status of a Motor Operated Valve.
25.00 (CAD)
Input Bypass
The module provides an alarm bypass function for Analog and discrete inputs.
25.00 (CAD)
PAx 2.0 HMI Simplified Lib 001
Used to replace standard faceplates in PlantPAX 2.0
50.00 (CAD)
PID Lite
This module provides simplified PID control where the additional functions provided with the advanced PID block are not required.
25.00 (CAD)
DST (Daylight Saving Time)
This module alters the Daylight Saving Time setting of the PLC.
25.00 (CAD)
Shiftwise Run Time
This module allow for the run time value of a piece of equipment (e.g. pump) to be recorded for a maximum of 3 shifts.
25.00 (CAD)
PLC Clock (Read Write)
This AOI reads the current time/date and also allows the PLC clock to be updated.
25.00 (CAD)
Flasher Bit
Flashes an output based on user specified time values.
25.00 (CAD)
P_DIn-FacePlate_Simplified_20
Used to replace standard faceplate in PlantPAX 2.0
25.00 (CAD)
Motor (Fixed Speed)
This AOI controls a single speed motor and is interfaced with a HMI graphic.
25.00 (CAD)
MSD
This module controls a Motorized Smoke Dampers used in Environmental control systems.
25.00 (CAD)
Analog_Input_Scaled
Scales analog input
25.00 (CAD)
NOT_8
This module inverts the state of each input to the corresponding output.
25.00 (CAD)
Integrator
This function integrates anything you may need. Just set the parameters and you will have the output ready to use.
35.00 (CAD)
Sort
This modules sorts 10 real values into order, either highest-to-lowest or lowest-to-highest.