All Products

View all the products
Picture of Motor
Motor

Module for control motor in 2 directions

15.00 (CAD)
Global object, faceplate and AOI
INTERLOCK_32x1

This package is a complete solution that allows fast development and configuration of interlocks, a task that normally takes a lot of time. This works with 32 inputs and comes with four faceplate's sizes suitable for all types of HMI and SCADA systems.

25.00 (CAD)
Picture of Double Block & Bleed Tightness Test
Double Block & Bleed Tightness Test

The module is used to prove the seal of a valve.

25.00 (CAD)
Picture of Ramp Down
Ramp Down

The module decreases a value when triggered.

25.00 (CAD)
Product Barcode_SerialNos_Validation_IndirectAddressing
Product Barcode_SerialNos_Validation_IndirectAddressing

Indirect Addressing Concept For Scanning No.of Products to Avoid Duplicate Barcode Number when products are travelling through conveyor

30.00 (CAD)
Picture of SensCom
SensCom

The AOI provides a sensor signal to be treated according to its authenticity proof. The AOI is mainly developed to be used with any industrial protocol sensor/gateway/module (ex. Modbus sensor/gateway, remote IO etc), but could be used with any analog measured value.

20.00 (CAD)
Picture of Pulse Width Modulator (PWM)
Pulse Width Modulator (PWM)

The module produces a pulsed output based on the two input parameters.

25.00 (CAD)
Picture of Julian Day of Year
Julian Day of Year

The module determines the day of the year and presents the value as a string.

25.00 (CAD)
Picture of Module Network Monitor
Module Network Monitor

This AOI is to be used in order to monitor and check for any Data interruption between the MAIN CPU and the selected connected MODULE.

25.00 (CAD)
FC valve AOI
TYPICAL FC VALVE

Contains a typical for digital Fail Close Valves with 1 solenoid and 2 limit switches. The valve closes if it is tripped or a command to close is set on it. Can receive manual operations like opening and closing the valve from a button(on the HMI).

19.99 (CAD)
Picture of DayOfTheWeek
DayOfTheWeek

reads the PLC date and returns a value from 1 to 7 as an integer value for the day of the week

25.00 (CAD)
AIM
TYPICAL ANALOG INPUT with M.O.S.

Takes the input from the analog card. Outputs a scaled value and HH/HI/LO/LL alarms. Maintenance override switch functionality.

19.99 (CAD)
Result
TYPICAL ANALOG INPUT

Takes the input from the analog card.Outputs a scaled value and HH/HI/LO/LL alarms. Can be imported as a library and it will create all the variables automatically or can be imported as a AOI.

15.00 (CAD)
Picture of Bang-Bang Control
Bang-Bang Control

The module provides On-Off control based on 2 setpoints.

25.00 (CAD)
Picture of Event Per Hour
Event Per Hour

This module records the number of events in a 1 hour period.

25.00 (CAD)
Picture of E3Plus Interface (DeviceNet)
E3Plus Interface (DeviceNet)

This module is used to interface the data read from and written to a E3Plus Relay using DeviseNet.\

25.00 (CAD)