All Products

View all the products
Picture of Spin Coater PLC Code & HMI
Spin Coater PLC Code & HMI

Spin coating is a technique used to spread uniform thin films on flat substrates by centrifugal force. Spin Coater ladder language programming and Human Machine Interface using PLC and touch panel

252.00 (CAD)
Picture of AB PV800 HMI and Siemens S7-1214 communication
AB PV800 HMI and Siemens S7-1214 communication

In this project AB HMI PV800 connect to Siemens S7-1214 PLC on MODBUS TCP/IP communication, and also this project has browser based scada (HMS EWON flexy 202 with GSM card and Viewon)

200.00 (CAD)
Picture of Digital control of proportional flow control valves for smooth acceleration and decceleration of several actuators
Digital control of proportional flow control valves for smooth acceleration and decceleration of several actuators

User-defined function block for CCW aimed at controlling hydraulic systems comprising of a single general proportional control valve and up to 4 bidirectional 4/3 on/off valves.

60.00 (CAD)
Picture of eTech_DOW_Date_AOI - ( RS/Studio5000)
eTech_DOW_Date_AOI - ( RS/Studio5000)

Studio 5000 - Rockwell Automation AOI Outputs - Julian Day, Day of Week, Is Leap Year and Current CPU Date/TIME

50.00 (CAD)
Picture of Anti Fire Fighting Sprinkle System
Anti Fire Fighting Sprinkle System

This module is for anti fire fighting sprinkle system. It consists of one pressure switch and two pumps controlled via VFD.

50.00 (CAD)
SCP_STEP7_V5.x
SCP Instruction for STEP 7 V5.x (S7-300 & S7-400)

This is a converted function block from the RS Logix 500 SCP instruction with added features. For STEP 7 V5.x (S7-300 & S7-400 PLCs)

50.00 (CAD)
Picture of PAx 2.0 HMI Simplified Lib 001
PAx 2.0 HMI Simplified Lib 001

Used to replace standard faceplates in PlantPAX 2.0

50.00 (CAD)
Picture of CM_AI
CM_AI

The Analog Input AOI Control Module is used to condition analog input signals into usable values for indication, control, and/or alarming by components of the PLC program or other systems (HMI, MES, etc.) Note: Programmed followed ISA88, ISA95 and ISA106 Standard

35.00 (CAD)
Picture of Integrator
Integrator

This function integrates anything you may need. Just set the parameters and you will have the output ready to use.

35.00 (CAD)
Picture of For_Do_Loop_AOI
For_Do_Loop_AOI

Works exactly like a for do loop in higher programming language but used in ladder logic

30.00 (CAD)
Picture of CM_AO
CM_AO

The Analog Output AOI Control Module is used to condition an engineering unit analog output value into the proper range for analog output modules and devices. Note: Programmed followed ISA88, ISA95 and ISA106 Standard

30.00 (CAD)
Product Barcode_SerialNos_Validation_IndirectAddressing
Product Barcode_SerialNos_Validation_IndirectAddressing

Indirect Addressing Concept For Scanning No.of Products to Avoid Duplicate Barcode Number when products are travelling through conveyor

30.00 (CAD)